Showing posts with label Unit. Show all posts
Showing posts with label Unit. Show all posts

Friday, April 8, 2016

GSM - TRX Planning

ZTE Magic RRU consists of 6 ports to which 3 PA (power amplifiers) can be connected. Each PA supports 80 Watt linked with a sector/cell and the power is distributed uniformly among the TRXs connected to a PA. This means that with a minimum recommended power of 20 W per TRX, no more than 4 TRXs should be configured on one PA or sector. Thus, for a site having 3 sectors, 444 configuration is suitable.

Transmission requirement for TRX depends on multiple factors such as:

  • TRX configuration
  • Coding Scheme - Higher coding scheme (MCS-9) requires more transmission bandwidth
  • Number of static and dynamic PDCH configuration
  • Half Rate utilization
In general, a site with a 444 configuration, 2 static and 4 dynamic PDCHs per cell, 100% Half Rate utilization, and an average of MCS6 can be supported by 1 E1 (2.048 Mbps).

Tuesday, January 26, 2016

Base Station Solution

Base station solution can be classified into two types:

Macro: where BBU and RFU are part of the cabinet of the base station
Distributed: where the cabinet comprises of BBU and RRU. RRU can be deployed close to the antenna which reduces antenna loss and can contribute to enhanced coverage.

RRU can be singe mode or multimode (GSM, UMTS, and/or LTE). A typical RRU contains sub systems such as Transciever (TRX), Power Amplifier (PA)/LNA, and Duplexer (DFL).