Tuesday, December 22, 2015

UMTS Reselection Parameters

General parameters with typical network values of the three types of reselection in UMTS is presented below:

3G to 3G

  • qrxlevmin = -109 dBm     (min acceptable threshold of cell RSCP)
  • qqualmin = -18 dB           (min acceptable threshold of cell quality EcNo)

  • sintersearch =  10 dB   (f1,f2 case)
  • sintrasearch =  14 dB    (same frequency)

3G to 2G

  • ssearchrat = 2dB            (indicates when to trigger measurements on GSM cells, increasing this value quickens while decreasing it delays the process)
  • treselect = 2s
  • qoffset1sn = 7dB for gsmrelation; 0 dB for utranrelation                                                       (Source and target signal offset when reselection strategy is RSCP)
  • qoffset2sn = 0 dB                 (Source and target signal offset when reselection strategy is EcNo)

2G to 3G

  • FDDqRSCPmin = -102 dBm
  • FDDqmin = -12 dB

Equation

The equations on which the decision is made using these parameters are:

For EcNo based reselection:

Squal <= sintrasearch     OR        sintersearch           OR            ssearchrat

where Squal = qmeasured  -    qqualmin

Thus the equation becomes:

qmeas - qqualmin <= sintrasearch

qmeas  <= qqualmin + sintrasearch

Similarly, EcNo values can be replaced with RSCP for the RSCP based reselection.

No comments:

Post a Comment